EQUATORAdvanced AppliancesSERVICE MANUALSPARE PARTS CATALOGANDFirst Edition - October 2003COMBINATION WASHER-DRYERMODELS: EZ 1500EZ 2500 CEZ 3600 C/CE
TABLE 1EZ 3600 CEE8
9Pos. Part Number Part Name Pos. Part Number Part Name1 111100830 Top panel 25 119803003 Levelling leg1 111100926 Top panel 2500 C 26 116102761 Electr
TABLE 2EZ 3600 C10
TABLE 2EZ 3600 CEE11
12Pos. Part Number Part Name Pos. Part Number Part Name1 114200661 Porthole Diaphragm 28 114900269 Upper counterweight 2500 C1 114200670 Porthole diap
TABLE 313
14Pos. Part Number Part Name1 119803998 Control panel1 119804128 Control panel for CEE2 119803935 Knob4 112903471 Push button5 112400492 Soap dispense
TABLE 415
16Pos. Part Number Part Name1116102999Water valve 2500 C1116102549Water valve1116103135Water valve CEE2114200090Gasket3119400110Inlet hose4 116102995
TABLE 517
Table Of ContentsWARRANTY INFORAMTION 1TROUBLESHOOTING 2-6INSTALLATION 2WASH CYCLE 2-5DRY CYCLE 5-6SPARE PARTS CATALOG 7-18CABINET 7-9OSCILLATING GROU
18Pos. Part Number Part Name1 114200661 Porthole diaphragm1 114200670 Porthole diaphragm for 2500 C2 114200654 Gasket3 970196912 Clamp4 113300546 Heat
To help avoid electrical shock, no liveelectrical test of the Electronic Control Modulewill be made.Start by unplugging the unit, then remove theconne
20Testing the Drive Motor(7 and 10 pin connector)
22TIMER CHART
EQUATOR SERVICE AGREEMENTDear Service Agent:Welcome to the world of Equator! We are pleased to appoint you as an EquatorAuthorized Service Agent. Equa
WARRANTY INFORMATIONYour Equator appliance is protected by this warranty under normal,personal, family or household use (1 Year), and limited commerci
Troubleshooting2Problem Possible Cause Repair procedure1. Machine vibratingor vibrating noise1a. Shipping brackets notremoved1a. Open back of m achine
3Problem Possible Cause Repair Procedure1g. Timer1g. Set to start of regular wash cycle. Test for115 vac between high side of hot and cold waterinlet
4Problem Possible Cause Repair Procedure5. Noisy 5a. Not leveled. 5a. Adjust levelling legs, tighten lock nuts.5b. Foreign object in tub. 5b. Check tu
Problem Possible Cause Repair Procedure11. Machineoverfills.11a. Pressure Switch.11a.Unplug unit. With excessive water still intub, check for continui
6Problem Possible Cause Repair Procedure2b. Blower inoperative. 2b. Check for 115 vac at the blower motorterminals. Check motor resistance: 10 ohmsmax
TABLE 1EZ 3600 C7